Abstract:Objective To evaluate the sensitivity of two immunoassay kits for anti-Hepatitis A Virus (HAV) IgM. Method On the gold standard confirmed by assay-Abbott HAV-IgM, the sensitivity of the two kits for testing HAVIgM in China were evaluated. The correlation of S/CO value of the two kits with Abbott HAV-IgM were estimated. Results HAV IgM had a sensitivity and specificity of 94.3% and 85.2% respectively with Wantai test, while 97.1% and 91.3% respectively with Gaoda test. HAV-IgM (Abbott) showed a correlation of S/CO valuewith HAV-IgM (Wantai) test and HAV-IgM (Gaoda) test, respectively (r = 0.597 and 0.541, all P = 0.000). HAV-IgM (Wantai) test and HAV-IgM (Gaoda) test showed good consistency with HAV-IgM (Abbott) test, with a k-coefficients of 0.648 and 0.772, respectively. Conclusion HAV-IgM (Wantai) and HAV-IgM (Gaoda) have good detection performances, which provides important reference for clinical detection and seroepidemiology statistics.